Manual No. 25-ULGPMU01-01 Series OPT Handheld
CCD Scanner
Page 61
Redundant Decoding Settings
ZZ
Start/End
Program
Menu
-[[-
X0
No
redundancy
-Y1-
X1
Two times
redundant
-Y2-
%
X2
Three times
redundant
-Y3-
X3
Four times
redundant
-Y!-
Redundancy Settings - This is the number of times that a label must be correctly decoded before it is transmitted.
Selecting a higher redundancy count makes reading slower, but it reduces the probability of reading errors,
especially when labels of poor definition are used.
Positive and Negative Bar Codes
ZZ
Start/End
Program
Menu
-[[-
V2
Positive
bar codes
-W3-
V4
Both positive
and negative
bar codes
-W5-
%
Positive and Negative Bar Codes - Usually bar codes are printed black on white, but sometime white on black.
These labels are called positive and negative, respectively.