Opticon
OPL 9712
Specifications Manual
13
8.3.3. Tilt Angle
Scanning performance is guaranteed when γ = ±20°
γ
=
2
0
°
γ
=
2
Figure 6: Tilt angle
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
Distance: 90 mm from the edge of the data collector
Label:
Pitch, Skew Angle
PCS = 0.9, Resolution = 0.25 mm, Symbology = 9-digit Code 39,
Quiet Zone = 10 mm, N/W Ratio = 1:2.5
Dead Zone, Tilt Angle
PCS = 0.9, Resolution = 0.26 mm, Symbology = 13-digit JAN, Quiet Zone = 10 mm
Angle: Curvature: R = , Skew Angle = β +15° (for measuring Pitch Angle and Tilt Angle)