Troubleshooting
A. If LEDs do not light up when installation
instructions are followed:
Make sure there is power to the system
Recycle computer power
Confirm computer fuses are ok.
Check for loose cable connection
B. If the wand tip lights up, Good Read beep is
audible, but outputs random characters to
screen, verify that the wand has been pro-
grammed to the correct settings:
Confirm selected Computer Type
matches the type of computer being used.
Adjust Intercharacter Delay settings.
Intercharacter delay settings will vary
according to the computer type being
used.
Is a dedicated file server being used?
Non-dedicated file serves may cause
problems for a Wedge interface. Opticon
recommends using an RS232C CCD smart
wand on non-dedicated file servers.
3. If the wand tip lights up, but Good Read
beep is not heard and no data appears on the
computer:
Is the bar code label readable? Does it
meet bar code specifications?
Does the smart wand read other bar code
labels? (If yes, the non-reading label may
be a label which the smart wand is not
programmed to decode.)
NOTE: If after performing these checks, the
smart wand is still not functioning, contact your
distributor or call Opticon Technical Support at
800-636-0090.